E-comfort instant water heater
DBX Next
Energy efficiency class A
(scale: A+ to F)
- DBX 18 Next: 18 kW, 400 V
- DBX 21 Next: 21 kW, 400 V
- DBX 24 Next: 24 kW, 400 V
This is where the DBX Next is used.
-
Handwashbasin
-
Shower
-
Bath tub
-
Kitchen sink
The cost-effective
alternative .
The basic unit of our series of electronic instant water heaters comes without any user controls. That’s why the DBX Next is surprisingly inexpensive.
- Electronically controlled basic instantaneous water heater without controls
- Exceptionally low start-up water flow rate from 1.5 l/min thanks to innovative water flow technology
- Exceptionally air-resistant heating system thanks to new type of heating channel arrangement
- Automatic adjustment of output to flow rate and inlet temperature, outlet temperature set to 50 °C at the factory
- The outlet temperature can be adjusted in the unit between 30 °C and 60 °C
- Bare wire heating system IES ensures a longer service life, less calcification and is efficient and easy to maintain
- Electronic safety system with air bubble detection, temperature and pressure shut-off
- Easy installation thanks to free mounting space and variable connection options
- Dimensions (height × width × depth): 46.6 × 23.0 × 9.7 cm
Technical data
>
Data. Values. Facts.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
1) Temperature increase e.g. from 12 °C to 40 °C, mixed water
2) Limited flow amount for optimal temperature increase
3) Alternatively connectable to 380 V
Downloads
>
Media type | Title | Date | Size | |
---|---|---|---|---|
Product information sheet DBX-Next-PI-en.pdf 20.07.2023 > download |
Product information sheet | DBX-Next-PI-en.pdf | 20.07.2023 |
381 kB > download |
Operating and installation instructions DBX-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr.pdf 17.02.2023 > download |
Operating and installation instructions | DBX-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr.pdf | 17.02.2023 |
22,0 MB > download |
Older versions> | ||||
Operating and installation instructions | DBX-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr-09-2022.pdf> download | > download | ||
Operating and installation instructions | DBX-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr-08-2020.pdf> download | > download | ||
Further versions on request | ||||
Quick guide DBX-Next-KA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr.pdf 27.02.2023 > download |
Quick guide | DBX-Next-KA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr.pdf | 27.02.2023 |
4,3 MB > download |
Older versions> | ||||
Quick guide | DBX-Next-KA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr-09-2022.pdf> download | > download | ||
Quick guide | DBX-Next-KA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr-12-2021.pdf> download | > download | ||
Quick guide | DBX-Next-KA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr-08-2020.pdf> download | > download | ||
Further versions on request | ||||
Installation accessories DX3-Montageschablone-de-en-fr-nl-pl-cs-sk-pt-es-sv.pdf 13.11.2018 > download |
Installation accessories | DX3-Montageschablone-de-en-fr-nl-pl-cs-sk-pt-es-sv.pdf | 13.11.2018 |
370 kB > download |
Safety instructions Sicherheitshinweise-Durchlauferhitzer-de-en-fr-nl-pt-es-pl-sv-cs-sk-bg-no-fi-ru-sr-el-it-tr-ro.pdf 03.11.2023 > download |
Safety instructions | Sicherheitshinweise-Durchlauferhitzer-de-en-fr-nl-pt-es-pl-sv-cs-sk-bg-no-fi-ru-sr-el-it-tr-ro.pdf | 03.11.2023 |
371 kB > download |
Energy label DBX24-Next-Energielabel_2020.pdf 28.03.2023 > download |
Energy label | DBX24-Next-Energielabel_2020.pdf | 28.03.2023 |
231 kB > download |
Energy label DBX18-Next-Energielabel_2020.pdf 28.03.2023 > download |
Energy label | DBX18-Next-Energielabel_2020.pdf | 28.03.2023 |
232 kB > download |
Energy label DBX21-Next-Energielabel_2020.pdf 28.03.2023 > download |
Energy label | DBX21-Next-Energielabel_2020.pdf | 28.03.2023 |
231 kB > download |
ErP product sheet DX3.1-DBX18-Next-DBX21-Next-DBX24-Next-ErP-Produktdatenblatt.pdf 27.03.2023 > download |
ErP product sheet | DX3.1-DBX18-Next-DBX21-Next-DBX24-Next-ErP-Produktdatenblatt.pdf | 27.03.2023 |
102 kB > download |
CE Conformity CE-Konformitaetserklaerung-nach-RED+RoHS3-DX3-2021-10.pdf 05.11.2021 > download |
CE Conformity | CE-Konformitaetserklaerung-nach-RED+RoHS3-DX3-2021-10.pdf | 05.11.2021 |
1,3 MB > download |
Product photo DBX-Next-Produktfoto.jpg 22.12.2020 > download |
Product photo | DBX-Next-Produktfoto.jpg | 22.12.2020 |
600 kB > download |
Image photo DBX-Next-Anwendungsfoto.jpg 21.09.2020 > download |
Image photo | DBX-Next-Anwendungsfoto.jpg | 21.09.2020 |
793 kB > download |
Catalogue CLAGE-Complete-catalogue-en.pdf 16.10.2024 > download |
Catalogue | CLAGE-Complete-catalogue-en.pdf | 16.10.2024 |
11,0 MB > download |
Catalogue CLAGE-Brochure-en.pdf 31.01.2023 > download |
Catalogue | CLAGE-Brochure-en.pdf | 31.01.2023 |
5,7 MB > download |
Hotnews CLAGE_Hotnews_2023-EN-online.pdf 10.03.2023 > download |
Hotnews | CLAGE_Hotnews_2023-EN-online.pdf | 10.03.2023 |
13,9 MB > download |
Price list CLAGE-Product-Price-List-PPL-en.pdf 10.05.2023 > download |
Price list | CLAGE-Product-Price-List-PPL-en.pdf | 10.05.2023 |
6,6 MB > download |
BIM DX3-DBX-Next-001.ifc 02.11.2021 > download |
BIM | DX3-DBX-Next-001.ifc | 02.11.2021 |
8,2 MB > download |
BIM DX3-DBX-Next-001.rfa 02.11.2021 > download |
BIM | DX3-DBX-Next-001.rfa | 02.11.2021 |
1,3 MB > download |
Datanorm Datanorm.zip 03.06.2024 > download |
Datanorm | Datanorm.zip | 03.06.2024 |
40 kB > download |
GAEB GAEB.zip 03.06.2024 > download |
GAEB | GAEB.zip | 03.06.2024 |
725 kB > download |
Accessories
>
RDX 3 (optional)
If required, the universal mounting frame RDX 3 is available as an accessory, with which the electrical connection can be made at any point behind the device. The IP protection class of the device with RDX 3 is IP24. With electrical wiring and pipe extensions. For difficult installation conditions, e.g. replacement of a flow heater with different connections. Compensates for tile projections or wall unevenness. Installation only by a specialist.
RDX 3: Part no. 3200-36100
- Installation instructionsRDX3-MA-de-en.pdf (438 kB)
UDX (optional)
Pipe assembly for undersink installation with water connections, top flush-mounted G ⅜ inch (basic mounting kit RDX required).
UDX: Part no. 3200-34110
- Operating and installation instructionsUDX-GMA-de-en.pdf (494 kB)
VDX (optional)
Pipe assembly for offset installation or reversed water connections when exchanging gas water heaters (basic mounting kit RDX required).
VDX: Part no. 3200-34120
- Operating and installation instructionsVDX-GMA-de-en.pdf (564 kB)
Interesting features.
-
Cost-saving
-
Instantly at the right temperature
-
Short water paths