All about instantaneous water heaters! >
×

E-comfort instant water heater
DCX Next

E-comfort instant water heater DCX Next

Energy efficiency class A

(Scale: A+ to F)

  • DCX Next: 18/21/24/27 kW, 400 V

This is where the DCX Next is used.

  1. Handwashbasin

    Handwashbasin

  2. Shower

    Shower

  3. Bath tub

    Bath tub

  4. Kitchen sink

    Kitchen sink

Saving energy in the bathroom is that easy!

The electronic E-comfort instant water heater DCX Next is designed for easy operation. One of the five typical hot water temperatures can be selected using the sensor button. Each temperature is indicated by an easily understandable colour display.

  • Electronically controlled instantaneous water heater with simple operating concept
  • One-button control panel for quick and easy temperature selection in five levels: 35 °C, 38 °C, 42 °C, 48 °C and 55 °C
  • Electronic safety system with air bubble detection, temperature and pressure shut-off
  • Temperature stable up to the power limit. TWIN TEMPERATURE Control TTC® ensures precise temperature control to the degree, even with fluctuations in water pressure.
  • With Multiple Power System MPS® the maximum power consumption is determined at installation: 18, 21, 24 or 27 kW, 400 V
  • Suitable for water-saving taps due to particularly low switch-on water quantity from 1.5 l/min thanks to innovative water flow technology
  • Dimensions (height × width × depth): 46.8 × 23.9 × 9.6 cm

Technical data

>

Data. Values. Facts.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
E-comfort instant water heater DCX Next
Handwashbasin Shower Bath tub Kitchen sink      
DCX Next
Part number
Nominal power rating 1) (variably adjustable due to MPS) at 400 V [kW]
Permissible operating pressure [MPa (bar)] 2)
Water connections (thread connections)
Hot water output at Δt = 28 K 3) [l/min]
Switch-on flow rate [l/min]
Maximum flow rate 4) [l/min]
Supply voltage [3~ / PE 400 V AC] Permanent connection 5)
Nominal current at 400 V [A]
Required cable diameter [mm²]
Maximum inlet temperature [°C]
Solar-ready 6)
Protection class
Specific water resistance at 15 °C [Ωcm] ≥
Weight filled with water [kg], approx.
3200-36300
18 21 24 27
1 (10) 1 (10) 1 (10) 1 (10)
G ½" G ½" G ½" G ½"
9.2 10.7 12.3 13.8
1.5 1.5 1.5 1.5
8.0 8.0 8.0 8.0
26 30 35 39
4.0 4.0 6.0 6.0
70 70 70 70
IP 25 IP 25 IP 25 IP 25
1100 1100 1100 1100
4.2 4.2 4.2 4.2

1) The selected power rating determines the values of nominal current, cable diameter and hot water output

2) Also approved for pressureless operation

3) Temperature increase e.g. from 12 °C to 40 °C, mixed water

4) Limited flow amount for optimal temperature increase

5) Alternatively connectable to 380 V

6) Suitable for reheating

Downloads

>

Media type Title Date Size

Product information sheet

DCX13-Next-DCX-Next-PI-en.pdf

20.07.2023

> download
Product information sheet DCX13-Next-DCX-Next-PI-en.pdf 20.07.2023 499 kB
> download

Installation instructions

DCX-Next-Beiblatt-Erstinbetriebnahme-de-en.pdf

18.03.2020

> download
Installation instructions DCX-Next-Beiblatt-Erstinbetriebnahme-de-en.pdf 18.03.2020 369 kB
> download

Installation instructions

DX3-Beiblatt-mit-Armatur-de-en-fr-02-2023.pdf

15.02.2023

> download
Installation instructions DX3-Beiblatt-mit-Armatur-de-en-fr-02-2023.pdf 15.02.2023 418 kB
> download

Operating and installation instructions

DCX-Next-DCX13-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr.pdf

22.02.2023

> download
Operating and installation instructions DCX-Next-DCX13-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr.pdf 22.02.2023 29,1 MB
> download
  Older versions> 
 Operating and installation instructionsDCX-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr-06-2022.pdf> download> download
 Operating and installation instructionsDCX-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr-08-2020.pdf> download> download
 Operating and installation instructionsDCX-Next-Online-GMA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr-07-2020.pdf> download> download
 Operating and installation instructionsDCX-Next-Online-GMA-de-en-02-2020.pdf> download> download
  Further versions on request 

Quick guide

DCX-Next-DCX13-Next-KA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr.pdf

20.06.2023

> download
Quick guide DCX-Next-DCX13-Next-KA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr.pdf 20.06.2023 6,6 MB
> download
  Older versions> 
 Quick guideDCX-Next-DCX13-Next-KA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr-01-2023.pdf> download> download
 Quick guideDCX-Next-DCX13-Next-KA-de-en-fr-nl-pt-es-pl-ru-cs-sk-bg-sr-06-2021.pdf> download> download
 Quick guideDCX-Next-KA-de-en-02-2020.pdf> download> download
  Further versions on request 

Image-only instructions

DX3-400V-BiA-mit-DMB.pdf

14.12.2021

> download
Image-only instructions DX3-400V-BiA-mit-DMB.pdf 14.12.2021 2,0 MB
> download
  Older versions> 
 Image-only instructionsDX3-400V-BiA-mit-DMB-03-2020.pdf> download> download
  Further versions on request 

Installation accessories

DX3-Montageschablone-de-en-fr-nl-pl-cs-sk-pt-es-sv.pdf

13.11.2018

> download
Installation accessories DX3-Montageschablone-de-en-fr-nl-pl-cs-sk-pt-es-sv.pdf 13.11.2018 370 kB
> download

Safety instructions

Sicherheitshinweise-Durchlauferhitzer-de-en-fr-nl-pt-es-pl-sv-cs-sk-bg-no-fi-ru-sr-el-it-tr-ro.pdf

03.11.2023

> download
Safety instructions Sicherheitshinweise-Durchlauferhitzer-de-en-fr-nl-pt-es-pl-sv-cs-sk-bg-no-fi-ru-sr-el-it-tr-ro.pdf 03.11.2023 371 kB
> download

Energy label

DCX-Next-Energielabel.pdf

28.03.2023

> download
Energy label DCX-Next-Energielabel.pdf 28.03.2023 231 kB
> download

ErP product sheet

DCX-Next-ErP-Produktdatenblatt.pdf

27.03.2023

> download
ErP product sheet DCX-Next-ErP-Produktdatenblatt.pdf 27.03.2023 102 kB
> download

CE Conformity

CE-Konformitaetserklaerung-nach-RED+RoHS3-DX3-2023-04.pdf

21.04.2023

> download
CE Conformity CE-Konformitaetserklaerung-nach-RED+RoHS3-DX3-2023-04.pdf 21.04.2023 3,1 MB
> download

Product photo

DCX-Next-Produktfoto-frontal.jpg

28.09.2020

> download
Product photo DCX-Next-Produktfoto-frontal.jpg 28.09.2020 37 kB
> download

Product photo

DCX-Next-Produktfoto-rechts.png

28.09.2020

> download
Product photo DCX-Next-Produktfoto-rechts.png 28.09.2020 253 kB
> download

Product photo

DCX-Next-Produktfoto.jpg

22.12.2020

> download
Product photo DCX-Next-Produktfoto.jpg 22.12.2020 661 kB
> download

Image photo

DCX-Next-Milieufoto.jpg

28.09.2020

> download
Image photo DCX-Next-Milieufoto.jpg 28.09.2020 845 kB
> download

Catalogue

CLAGE-Complete-catalogue-en.pdf

20.12.2024

> download
Catalogue CLAGE-Complete-catalogue-en.pdf 20.12.2024 11,0 MB
> download

Catalogue

CLAGE-Brochure-en.pdf

31.01.2023

> download
Catalogue CLAGE-Brochure-en.pdf 31.01.2023 5,7 MB
> download

Hotnews

CLAGE_Hotnews_2023-EN-online.pdf

10.03.2023

> download
Hotnews CLAGE_Hotnews_2023-EN-online.pdf 10.03.2023 13,9 MB
> download

General

CLAGE-DX3-FlyerA4-en.pdf

01.10.2020

> download
General CLAGE-DX3-FlyerA4-en.pdf 01.10.2020 1,2 MB
> download

General

DX3-Falzflyer-en.pdf

23.07.2021

> download
General DX3-Falzflyer-en.pdf 23.07.2021 2,4 MB
> download

BIM

DX3-DCX-002.ifc

12.03.2020

> download
BIM DX3-DCX-002.ifc 12.03.2020 4,8 MB
> download

BIM

DX3-DCX-Next-DCX13-Next-003.rfa.zip

23.11.2020

> download
BIM DX3-DCX-Next-DCX13-Next-003.rfa.zip 23.11.2020 613 kB
> download

Datanorm

Datanorm.zip

03.06.2024

> download
Datanorm Datanorm.zip 03.06.2024 40 kB
> download

GAEB

GAEB.zip

03.06.2024

> download
GAEB GAEB.zip 03.06.2024 725 kB
> download

Accessories

>

RDX 3

RDX 3 (optional)

If required, the universal mounting frame RDX 3 is available as an accessory, with which the electrical connection can be made at any point behind the device. The IP protection class of the device with RDX 3 is IP24. With electrical wiring and pipe extensions. For difficult installation conditions, e.g. replacement of a flow heater with different connections. Compensates for tile projections or wall unevenness. Installation only by a specialist.

RDX 3: Part no. 3200-36100

UDX

UDX (optional)

Pipe assembly for undersink installation with water connections, top flush-mounted G ⅜ inch (basic mounting kit RDX required).

UDX: Part no. 3200-34110

VDX

VDX (optional)

Pipe assembly for offset installation or reversed water connections when exchanging gas water heaters (basic mounting kit RDX required).

VDX: Part no. 3200-34120

Interesting features.

  1. Solar-compatible, suitable for reheating

    Solar-compatible, suitable for reheating

  2. Cost-saving

    Cost-saving

  3. Instantly at the right temperature

    Instantly at the right temperature

Installation video

Similar products:

E-comfort instant water heater DEX Next
DEX Next: 18/21/24/27 kW, 400 V
E-comfort instant water heater DCX Next L
DCX Next L: 18/21/24/27 kW, 400 V
E-comfort instant water heater DCX 13 Next
DCX 13 Next: 11/13.5 kW, 400 V
E-comfort instant water heater DLX Next
DLX 18 Next: 18 kW, 400 V
DLX 21 Next: 21 kW, 400 V
DLX 24 Next: 24 kW, 400 V